84
2011 Selection Guide
1. Select box application (freezer or refrigerator) and volume, in cubic feet
2. Choose evaporator appropriate for that application ("x" marks the spot)
3. Choose compressor/condensing unit.
4. Select options and/or upgrades
3 5 10 15 20
2.5
5 8 10
Capri 35 Capri 50 W35
W50
K35
K50 Capri35K Capri50K
Flat, All Aluminum
80F
13x9.5"
x
130F
24.75x8.25"
x x
200F
42x10.5"
x x x x
380F
39.2x14.5"
x x x x
Flat, Stainless
180F-SS
22x12"
x
380F-SS
41.3x16"
x x
Bin Shaped
250B
10x11 5x6"
x x
Freezer:
$
$
Pump not included
Paris 35
Box volume, cu ft (max)
Includes Keel Cooler
Includes Keel Cooler
Refrigerator:
ABS shroud
Fixed speed
Air Cooled
Stainless steel fan shroud
Keel & Air Cooled
Keel Cooled
With manual speed selector
With manual speed selector
With manual speed selector
With manual speed selector
Water Cooled
EVAPORATORS
CONDENSING UNITS
START HERE
250B
10x11.5x
x
340B
15x11.5x6"
x x
Horizontal, w/door
130H
10x2.75x8.5"
x
160H
12.5x4.5x8.5"
x x
340H
15x6x11.5"
x x
(340B with Lid Kit)
Bare-Bones Keel Cooler
- Not encased in sintered bronze. Not available with zincs.
All Keel Cooled systems
Zincs option for Keel Cooler
- Available for boats with no bonding system and zinc
All Keel Cooled systems
Guardian
upgrade
- Digital thermostat-thermometer, manual speed control, fault light
All systems
Merlin
Smart Speed Control upgrade
- Automatic compressor speed control with indicator light
All systems
Coastal MK II digital thermostat upgrade
- Remote temperature display and control panel
All systems
Control Module AC/DC upgrade
- Switches automatically from 12/24v to 110v/220v when available
All systems
Flo-Jet 12v raw water pump
- Self-priming, can supply up to three "W" units
Water cooled systems only
Spillover fan kit, mechanical
- Mounts on dividing wall. See note (1) below
All systems
Spillover fan kit, digital
- Fan mounts on dividing wall, control panel remote
All systems
Bracket for bulkhead mounting
- Stainless steel bracket for bulkhead mount, W and K
W and K compressors
1 - For spillover systems: Double the freezer volume, add to refer volume, consider box as all refer. Ex: 9 cu ft refer + 3 cu ft frz, consider as 15 cu ft refer
2 - System suggestions based on minimum of 3" closed cell polyurethane foam insulation in refrigerator, minimum of 4" in freezer
3 - Evaporator sizing is overall, in inches, includes tubing and is approximate
Notes:
Add:
Add:
Add:
3
OPTIONS and UPGRADES
:
Add:
Add:
Add:
Add:
Add:
Add:
Add:
4 - Prices and conditions subject to change without notice